ORGANIC COOLED REACTOR STUDY. PART 1. SUMMARY OF STUDY. PART 2. 300 MW POWER PLANT CONCEPTUAL DESIGN. PART 3. REACTOR CONCEPT EVALUATION. PART 4. 75 MW POWER PLANT CONCEPTUAL DESIGN. PART 5. 300 MW COAL-FIRED POWER PLANT COMPARISON STUDY

Technical Report ·
OSTI ID:4214225
Calif. Various design possibilities and variations thereof are evaluated to determine the specific concept and size most likely to result in economic power generation. A conceptual design is prepared in sufficient detail to estimate capital costs, fuel cycle costs, operating costs, research and development work required, and operating characteristics. The reductions in ultimate costs that might be achieved by multiple units are evaluated. A parallel conceptual design and evaluation effort on a 75 Mw(e) organic cooled and moderated reactor is reported. The results of a study to compare the costs for a conventional fossil fueled power plant with an OCMR power plant are presented. Based on 1963 costs, the power generation costs are 6.77, 8.12, and 13.12 mills/ kwh for a 300 Mw(e) coal-fired plant, a 300 Mw(e) OCMR plant, and a 75 Mw(e) OCMR plant, respectively. (W.D.M.)
Research Organization:
Bechtel Corp., San Francisco; Atomics International Div., North American Aviation, Inc., Canoga Park, Calif.
NSA Number:
NSA-13-020732
OSTI ID:
4214225
Report Number(s):
TID-8501
Country of Publication:
United States
Language:
English

Similar Records

Conceptual design of a 50 MW central station photovoltaic power plant
Journal Article · Thu Sep 01 00:00:00 EDT 1983 · IEEE Trans. Power Appar. Syst.; (United States) · OSTI ID:5449174

ECONOMIC EVALUATION OF A 300-Mw(e) SUPERCRITICAL PRESSURE POWER REACTOR
Technical Report · Thu Jun 01 00:00:00 EDT 1961 · OSTI ID:4781594

Conceptual Design for a 75 MWe Mixed Spectrum Superheating Reactor Power Plant
Technical Report · Sat Feb 24 23:00:00 EST 1962 · OSTI ID:4765203