Title: LOSS OF LEVEL IN D/P CELL REFERENCE CHAMBERS. SECTION I. FIRST PERFORMANCE. CORE 1, SEED 1

Technical Report ·
OSTI ID:4213805

Investigations were made to determine the reason for the decrease in the liquid levels of the reference chambers serving the reactor plant remote liquid level indicators. The remote gages and the local liquid level gages agreed closely for the Reactor Plant Component Cooling Water Expansion Tank and the Coolant Discharge and Vent System flash tank and blow-off tank. There appeared to be no loss of water from the D/P cell reference chambers for these two systems over the period of the test. There was no definite indication of leakage from the Valve Operating system reference chamber, however, the differences between remote indicator readings and the sight glass readings are attributed to sticking of the ball check valve on the upper sight glass, inaccuracy of the readings, and instrument error. (W.L.H.)

Research Organization:
Duquesne Light Co., Shippingport, Penna.
NSA Number:
NSA-14-004937
OSTI ID:
4213805
Report Number(s):
AECU-4517
Resource Relation:
Other Information: Test Results DL-S-279 (RNI-23). Orig. Receipt Date: 31-DEC-60
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

15 - Foot Bubble Chamber : Safety Report - Volume 3
Program Document · Sat Jul 01 00:00:00 EDT 1972 · OSTI ID:4213805

Integral Reactor Containment Condensation Model and Experimental Validation
Technical Report · Mon May 02 00:00:00 EDT 2016 · OSTI ID:4213805

Reference handbook: Level detectors
Technical Report · Thu Nov 15 00:00:00 EST 1990 · OSTI ID:4213805