LOSS OF LEVEL IN D/P CELL REFERENCE CHAMBERS. SECTION I. FIRST PERFORMANCE. CORE 1, SEED 1
Investigations were made to determine the reason for the decrease in the liquid levels of the reference chambers serving the reactor plant remote liquid level indicators. The remote gages and the local liquid level gages agreed closely for the Reactor Plant Component Cooling Water Expansion Tank and the Coolant Discharge and Vent System flash tank and blow-off tank. There appeared to be no loss of water from the D/P cell reference chambers for these two systems over the period of the test. There was no definite indication of leakage from the Valve Operating system reference chamber, however, the differences between remote indicator readings and the sight glass readings are attributed to sticking of the ball check valve on the upper sight glass, inaccuracy of the readings, and instrument error. (W.L.H.)