A magnetic-jack control safety rod is under development for the 45.5 Mw(th) Onganic Moderated Reactor. The rod is 'unitized,'' i.e., the poison element, drive, position indicator, and shock absorber are contained in a compact assembly which is inserted in a regular fuel channel opening in the core. Since all components of the rod are immersed in the reactor coolant, they must operate at or above the reactor inlet temperature, 550 F. Tests to develop components capable of operating under these conditions are described and results are reported. (auth)