RADIATION FROM THE OMRCA-I
Technical Report
·
OSTI ID:4208465
The maximum power level at which the OMR critical assembly may be operated is determined by the radiation level outside the exclusion area. At the beginning of the eeperimental program it was necessary to make a survey of the radiation from the reactor to determine the permissible operating levels. The effectiveness of the shieliding and the possibility of areas of high radiation levels were investigated. Radiation levels were measured for two different reactor conditions --with the maximum upper reflector thickness and with the moderator level approximately at the top of the fuel. (auth)
- Research Organization:
- Atomics International Div., North American Aviation, Inc., CAnoga Park, Calif.
- NSA Number:
- NSA-13-023112
- OSTI ID:
- 4208465
- Report Number(s):
- NAA-SR-Memo-4303
- Country of Publication:
- United States
- Language:
- English
Similar Records
PRECISION ORGANIC LEVEL GAUGE
ISRAEL RESEARCH REACTOR-I HAZARDS EVALUATION REPORT
Hazards Summary Report for the GCRE Critical-Assembly Experiments
Technical Report
·
Mon Jun 01 00:00:00 EDT 1959
·
OSTI ID:4239007
ISRAEL RESEARCH REACTOR-I HAZARDS EVALUATION REPORT
Technical Report
·
Thu Nov 30 23:00:00 EST 1961
·
OSTI ID:4792971
Hazards Summary Report for the GCRE Critical-Assembly Experiments
Technical Report
·
Tue Jul 22 00:00:00 EDT 1958
·
OSTI ID:4313269