RADIATION FROM THE OMRCA-I

Technical Report ·
OSTI ID:4208465
The maximum power level at which the OMR critical assembly may be operated is determined by the radiation level outside the exclusion area. At the beginning of the eeperimental program it was necessary to make a survey of the radiation from the reactor to determine the permissible operating levels. The effectiveness of the shieliding and the possibility of areas of high radiation levels were investigated. Radiation levels were measured for two different reactor conditions --with the maximum upper reflector thickness and with the moderator level approximately at the top of the fuel. (auth)
Research Organization:
Atomics International Div., North American Aviation, Inc., CAnoga Park, Calif.
NSA Number:
NSA-13-023112
OSTI ID:
4208465
Report Number(s):
NAA-SR-Memo-4303
Country of Publication:
United States
Language:
English