THERMAL SHOCK OF HRT FLANGES
Technical Report
·
OSTI ID:4206601
In reactor operations such as venting or dumping, some of the HRT flanges are subject to rapid temperature changes. Tests were conducted using 0.5- and 1-in. reactor type ring joint flanges subjected to thermal shocks from 25 to 300 deg C and from 300 to 25 deg C No apparent flange leaks were noted Bolt loadings following the tests were about the same in flanges having standard HRT carbon steel bolt-ferrules and in flanges having A-110AT titanium ferrules as well as in flanges having bolts without any fernules. (auth)
- Research Organization:
- Oak Ridge National Lab., Tenn.
- DOE Contract Number:
- W-7405-ENG-26
- NSA Number:
- NSA-14-006749
- OSTI ID:
- 4206601
- Report Number(s):
- CF-59-9-114
- Country of Publication:
- United States
- Language:
- English
Similar Records
DEVELOPMENT OF RING-JOINT FLANGES FOR USE IN THE HRE-2
SUMMARY OF HRT RUN 18
HRT LEAK DETECTION SYSTEM
Technical Report
·
Wed Dec 20 23:00:00 EST 1961
·
OSTI ID:4824236
SUMMARY OF HRT RUN 18
Technical Report
·
Fri Aug 26 00:00:00 EDT 1960
·
OSTI ID:4141847
HRT LEAK DETECTION SYSTEM
Technical Report
·
Thu Apr 19 23:00:00 EST 1956
·
OSTI ID:4332202