Ground water issue: Low-flow (minimal drawdown) ground-water sampling procedures
Technical Report
·
OSTI ID:420243
This paper is intended to provide background information on the development of low-flow sampling procedures and its application under a variety of hydrogeologic settings. The sampling methodology described in this paper assumes that the monitoring goal is to sample monitoring wells for the presence of contaminants and it is applicable whether mobile colloids are a concern or not and whether the analytes of concern are metals (and metalloids) or organic compounds.
- Research Organization:
- National Risk Management Research Lab., Ada, OK (United States). Subsurfaces Protection and Remediation Div.
- OSTI ID:
- 420243
- Report Number(s):
- PB-97-118822/XAB; EPA-540/S-95/504; TRN: 63581571
- Resource Relation:
- Other Information: DN: See also PB--95-269643; PBD: Apr 1996
- Country of Publication:
- United States
- Language:
- English
Similar Records
An analysis of low-flow ground water sampling methodology
Obtaining representative ground water samples in a fractured and karstic formation
Micro-purge low-flow sampling of uranium-contaminated ground water at the Fernald Environmental Management Project
Journal Article
·
Fri Mar 31 00:00:00 EST 2000
· Ground Water Monitoring and Remediation
·
OSTI ID:420243
Obtaining representative ground water samples in a fractured and karstic formation
Journal Article
·
Sun Mar 01 00:00:00 EST 1998
· Ground Water
·
OSTI ID:420243
Micro-purge low-flow sampling of uranium-contaminated ground water at the Fernald Environmental Management Project
Journal Article
·
Sun Oct 01 00:00:00 EDT 1995
· Ground Water Monitoring and Remediation
·
OSTI ID:420243