The candidate methods for semivolatile organic compounds are SW-846 Sampling Method 0010 and Analytical Method 8270, which are applicable to stationary sources. Two field tests were conducted using quadruple sampling trains with dynamic spiking were performed according to the guidelines of EPA Method 301. The first field test was performed at a site with low levels of moisture. The second test reported here was conducted at a chemical manufacturing facility where chemical wastes were burned in a coal-fired boiler. Poor recoveries obtained for the spiked analytes at the second test were attributed to wet sorbent from the sampling train, use of methanol to effect complete transfer of wet sorbent from the sampling module, and use of extraction techniques which did not effect a complete separation of methylene chloride from methanol. A procedure to address problems with preparation of samples from Method 0010 is included in the report.
Research Organization:
Radian Corp., Research Triangle Park, NC (United States)