HIGH TEMPERATURE AQUEOUS CORROSION OF ALUMINUM-PLUTONIUM AND ALUMINUM- SILICON-PLUTONIUM ALLOYS
Technical Report
·
OSTI ID:4199307
Al-Pu and Al-Pu-Si alloys were tested to determine their shont term corrosion in 350 and 360 deg C water. Tests of one day or less duration were done on bare as-cast and bare extruded alloys of varying Pu concentration. The performance of the alloys improves with increasing Pu up to 13%. Cold work drastically decreases performance. Addition of 12 wt% Si had the effect of rendering the Pu concentration resistant to attack for 24 hours. (J.R.D.)
- Research Organization:
- General Electric Co. Hanford Atomic Products Operation, Richland, Wash.
- DOE Contract Number:
- AT(45-1)-1350
- NSA Number:
- NSA-14-005554
- OSTI ID:
- 4199307
- Report Number(s):
- HW-61345
- Country of Publication:
- United States
- Language:
- English
Similar Records
AQUEOUS CORROSION OF ALUMINUM-PLUTONIUM ALLOYS
High Temperature Aqueous Corrosion of Aluminum-Uranium and Aluminum-Silicon-Uranium Alloys
INTERGRANULAR CORROSION OF ALUMINUM-URANIUM AND ALUMINUM-SILICON-URANIUM ALLOYS
Technical Report
·
Wed Oct 12 00:00:00 EDT 1960
·
OSTI ID:4075584
High Temperature Aqueous Corrosion of Aluminum-Uranium and Aluminum-Silicon-Uranium Alloys
Journal Article
·
Sat Jul 01 00:00:00 EDT 1961
· Corrosion (Houston)
·
OSTI ID:4039876
INTERGRANULAR CORROSION OF ALUMINUM-URANIUM AND ALUMINUM-SILICON-URANIUM ALLOYS
Technical Report
·
Thu Mar 13 23:00:00 EST 1958
·
OSTI ID:4329715