The corrosion loop operated at 90% utilization during this quarter. MOD SG-5 and SH-5 (Croloy 16-1) were removed from the loop after 4253 hours of testing without failure. MOD Sr-6 and SH-6 (Inconel) were removed after 3819 hours of testing. Testing of MIN-6 (Croloy 16-1) war terminated after 2767 hours. Testing of MIN-8 (Inconel) was terminated after 5296 hours. Post-test evaluation was completed on MIN-4, MIN-5 (Croloy 16-1) and MIN-9 (Inconel). Very little corrosion product was noted in the secondary of the Inconel vessel. Engineering design was imtiated on modifications to the corrosion loop. (For preceding period see MND-E-2007.) (auth)