THERMAL CYCLING AND LEAKAGE TESTS OF 12-INCH SODIUM VALVES
Tests of 12-in. scdium valves for use in the Hallam nuclear pcwer facility are descrihed. The valves were thermally cycled at 680 to 1100 tained F in a sodium loop and periodically examined for across-the-seat leakage. Results are tabulated. A discussion of testing procedure and recommendations is included. (J.R.D.)
- Research Organization:
- Atomics International. Div. of North American Aviation, Inc., Canoga Park, Calif.
- NSA Number:
- NSA-14-019057
- OSTI ID:
- 4178755
- Report Number(s):
- NAA-SR-Memo-3961
- Country of Publication:
- United States
- Language:
- English