THE EFFECTS OF SUPERIMPOSED FORCED AND FREE CONVECTION ON HEAT TRANSFER IN A VERTICAL RECTANGULAR DUCT
Journal Article
·
· Chem. Eng. Progr.
OSTI ID:4175470
Average and local experimental heat transfer coefficients are reported for a vertical duct of rectangular cross section where the mean air flow is from the top to the bottom of the duct and where heat is being added to the air at the walls. Results are given for a Reynolds number range of 1,800 to 10,000 based on the equivalent duct diameter for a duct length to equivalent diameter ratio of 69. The characteristic "dip region" in the transition zone between turbulent and laminar flow conditions is absent for Grashof numbers greater than 2 x 10/sup 5/ based on diameter. (auth)
- Research Organization:
- General Electric Co., Schenectady, N.Y.
- NSA Number:
- NSA-14-012690
- OSTI ID:
- 4175470
- Journal Information:
- Chem. Eng. Progr., Journal Name: Chem. Eng. Progr. Vol. Vol: 55, Symposium Ser. No. 29
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
THE EFFECTS OF SUPERIMPOSED FORCED AND FREE CONVECTION ON HEAT TRANSFER AND PRESSURE DROP IN A HORIZONTAL RECTANGULAR DUCT
Effects of electric field on mixed convection in a vertical channel
Stabilization of buoyancy-driven unstable vortex flow in mixed convection of air in a rectangular duct by tapering its top plate
Journal Article
·
Wed Dec 31 23:00:00 EST 1958
· Chem. Eng. Progr.
·
OSTI ID:4145284
Effects of electric field on mixed convection in a vertical channel
Book
·
Sat Dec 30 23:00:00 EST 1995
·
OSTI ID:445503
Stabilization of buoyancy-driven unstable vortex flow in mixed convection of air in a rectangular duct by tapering its top plate
Journal Article
·
Mon Jan 31 23:00:00 EST 2000
· Journal of Heat Transfer
·
OSTI ID:20067709