Measurements with a recuperative superfluid stirling refrigerator
Conference
·
OSTI ID:416761
- Los Alamos National Lab., NM (United States)
A superfluid Stirling refrigerator cooled to 168 mK using a 4.9 % {sup 3}He-{sup 4}He mixture and exhausting its waste heat at 383 mK. Cooling power versus temperature and speed is presented for 4.9%, 17%, and 36% mixtures. At the highest concentration, a dissipation mechanism of unknown origin is observed.
- OSTI ID:
- 416761
- Report Number(s):
- CONF-950722--
- Country of Publication:
- United States
- Language:
- English
Similar Records
Measurements with a recuperative superfluid Stirling refrigerator
A recuperative superfluid stirling refrigerator
A recuperative superfluid stirling refrigerator
Conference
·
Tue Aug 01 00:00:00 EDT 1995
·
OSTI ID:97022
A recuperative superfluid stirling refrigerator
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:47814
A recuperative superfluid stirling refrigerator
Conference
·
Thu Jul 01 00:00:00 EDT 1993
·
OSTI ID:10165867