Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Measurements with a recuperative superfluid stirling refrigerator

Conference ·
OSTI ID:416761
; ;  [1]
  1. Los Alamos National Lab., NM (United States)
A superfluid Stirling refrigerator cooled to 168 mK using a 4.9 % {sup 3}He-{sup 4}He mixture and exhausting its waste heat at 383 mK. Cooling power versus temperature and speed is presented for 4.9%, 17%, and 36% mixtures. At the highest concentration, a dissipation mechanism of unknown origin is observed.
OSTI ID:
416761
Report Number(s):
CONF-950722--
Country of Publication:
United States
Language:
English

Similar Records

Measurements with a recuperative superfluid Stirling refrigerator
Conference · Tue Aug 01 00:00:00 EDT 1995 · OSTI ID:97022

A recuperative superfluid stirling refrigerator
Conference · Fri Dec 30 23:00:00 EST 1994 · OSTI ID:47814

A recuperative superfluid stirling refrigerator
Conference · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:10165867