A HTS coil fabrication and joint development project was undertaken to develop the technology necessary for the production of a 5 T HTS insert coil for NMR applications. A series of minicoils are being fabricated to explore various construction options such as winding technique, structural support, and electrical insulation. The results from one of these coils are presented. Present conductor technology cannot produce the long length of conductor needed in the insert coil design, therefore, a means must be found to join several lengths of conductor together. Several joint prototypes are investigated.