DETERMINATION OF OXYGEN IN YTTRIUM FLUORIDE BY A VACUUM DISTILLATION TECHNIQUE

Journal Article · · Analytical Chemistry (U.S.) Formerly Ind. Eng. Chem., Anal. Ed.
OSTI ID:4166596

A conventional vacuum fusion gas analysis unit is used for the determination of oxygen in yttrium fluoride. The yttrium fluoride ia distilled from the furnace, leaving the less volatile oxygen-containing compounds to be reduced by the carbon crucible. Recoveries of oxygen are quantitative when a liquid reaction medium is provided for the reduction. The effect of platinum as the bath medium on the rate of carbon monoxide evolution is discussed. (auth)