skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: SURVEY OF THE RADIATION LEVELS IN THE CONTAINMENT VESSEL OF THE ENRICO FERMI ATOMIC POWER PLANT. PART V. GAMMA RADIATION LEVELS ON THE OPERATING FLOOR OF THE CONTAINMENT BUILDING. a. LEVELS ABOVE THE EQUIPMENT COMPARTMENT. Technical Memorandum No. 16

Technical Report ·
DOI:https://doi.org/10.2172/4153499· OSTI ID:4153499

The results are presented of a survey of calculated gamma-ray levels at many points on the surface of the operating floor of the containment building for the Enrico Fermi reactor. That portion of the floor surveyed lies directly above the equipment compartment. The calculations were made with the aid of an IBM-650 electronic computer. The main source of radioactivity which gives rise to gamma radiation above the floor is the radioactive sodium-24 in the primary coolant system. This system was considered to be completely filled with sodium, and activated to an equilibrium activity of 0.05 curies/cc, which corresponds to infinite reactor operation at 500 megawatts power. No fission product contamination was considered for these calculations. The operating floor is 5 feet thick and of concrete and steel. The results of the survey indicate that above the equipment compartment the surface dose on the operating floor will in no case exceed 0.9 mr/hr at the expected full operating power of 430 megawatts. Included as appendices are derivations and methods of corrections from one set of concrete and steel thicknesses to another. (auth)

Research Organization:
Atomic Power Development Associates, Inc., Detroit
Sponsoring Organization:
USDOE
DOE Contract Number:
AT(11-1)-476
NSA Number:
NSA-14-016468
OSTI ID:
4153499
Report Number(s):
TID-6032
Resource Relation:
Other Information: Orig. Receipt Date: 31-DEC-60
Country of Publication:
United States
Language:
English