PIQUA OMR-SPACING OF CAVITY LINER COOLING PIPES
Technical Report
·
OSTI ID:4151600
A study was conducted to determine the spacing of the cavity liner cooling pipes for maintenance of a maximum concrete temperature of 150 deg F in the biological shield. Results and recommendations are given along with descriptions of equipment, methods, and calculations. (J.R.D.)