Irradiation creep in the absence of swelling
Conference
·
OSTI ID:4151164
In-reactor creep of helium-pressurized 20 percent cold-worked Type 316 stain steel tubes was investigated at 375 to 575$sup 0$C. The creep strain was found to be in excess of the thermal creep of unirradiated specimens and the strain rate increased both with temperature and neutron fluence. These results are not clearly predicted by contemporary theories of creep during neutron irradiation. (auth)
- Research Organization:
- Hanford Engineering Development Lab., Richland, Wash. (USA)
- DOE Contract Number:
- E(45-1)-2170
- NSA Number:
- NSA-33-007869
- OSTI ID:
- 4151164
- Report Number(s):
- HEDL-SA--1036; CONF-751051--1; CONF-751101--41
- Country of Publication:
- United States
- Language:
- English
Similar Records
Dependence of irradiation creep on temperature and atom displacements in 20% cold worked type 316 stainless steel
Effects of large concentrations of helium on the mechanical properties of neutron-irradiated stainless steel
THE INFLUENCE OF COLD-WORK LEVEL ON THE IRRADIATION CREEP AND The Influence of Cold-Work Level on The Irradiation Creep and Swelling of AISI 316 Stainless Steel Irradiated as Pressurized Tubes In The EBR-II Fast Reactor
Conference
·
Wed Mar 31 23:00:00 EST 1976
·
OSTI ID:7327006
Effects of large concentrations of helium on the mechanical properties of neutron-irradiated stainless steel
Journal Article
·
Fri Oct 31 23:00:00 EST 1975
· J. Nucl. Mater., v. 58, no. 2, pp. 171-184
·
OSTI ID:4051008
THE INFLUENCE OF COLD-WORK LEVEL ON THE IRRADIATION CREEP AND The Influence of Cold-Work Level on The Irradiation Creep and Swelling of AISI 316 Stainless Steel Irradiated as Pressurized Tubes In The EBR-II Fast Reactor
Book
·
Fri Sep 01 00:00:00 EDT 2006
·
OSTI ID:966317