Scanning microsensors for measurement of local pH distributions at the microscale
Journal Article
·
· Journal of the Electrochemical Society
- Univ. of Illinois, Urbana, IL (United States)
Ion-selective pH microelectrodes were used to measure hydroxide ion concentration fields produced by electrochemical reduction of oxygen on 10 and 25 {micro}m Pt disk electrodes. The sensors were mounted on a scanning system, and the hydroxide concentration profiles over the disk electrodes were obtained. Data were compared with predictions based on the diffusion equation. The pH microelectrode was also used to verify the buildup of hydroxide ions generated by cathodic reaction on Al{sub 3}Fe that was in electrical contact with Al 6061 at the rest potential in 0.6 M NaCl.
- Sponsoring Organization:
- USDOE
- DOE Contract Number:
- FG02-91ER45439
- OSTI ID:
- 413397
- Journal Information:
- Journal of the Electrochemical Society, Journal Name: Journal of the Electrochemical Society Journal Issue: 8 Vol. 143; ISSN 0013-4651; ISSN JESOAN
- Country of Publication:
- United States
- Language:
- English
Similar Records
Influence of Fe-rich intermetallic inclusions on pit initiation on aluminum alloys in aerated NaCl
Quasi-simultaneous Measurements of Ionic Currents by Vibrating Probe and pH Distribution by Ion-selective Microelectrode
Current distribution and electrochemical environment in a cathodically protected crevice
Journal Article
·
Sun Jan 31 23:00:00 EST 1999
· Journal of the Electrochemical Society
·
OSTI ID:328209
Quasi-simultaneous Measurements of Ionic Currents by Vibrating Probe and pH Distribution by Ion-selective Microelectrode
Journal Article
·
Fri Dec 31 23:00:00 EST 2010
· Electrochemistry Communications
·
OSTI ID:1004140
Current distribution and electrochemical environment in a cathodically protected crevice
Journal Article
·
Sun Feb 28 23:00:00 EST 1999
· Corrosion
·
OSTI ID:349896