CAUSTIC STRESS CORROSION OF TYPE 347 STAINLESS STEEL
Technical Report
·
OSTI ID:4131228
The corrosion of type 347 stainless steel by aqueous solutions of NaOH and solutions of NaOH (16 to 60%) in sodium was studied on uranium-bend specimens, stressrupture specimens, and miniature boilers at 650 to 850 deg F. The aqueous solution produced stress-corrosion cracking at 650 deg F and the NaOH in sodium solution produced cracking at 850 deg F. The addition of sufficient disodium phosphate delayed or in some instances prevented cracking in dilute aqueous solutions. (C.J.G.)
- Research Organization:
- Knolls Atomic Power Lab., Schenectady, N.Y.; and Babcock and Wilcox Co. Research Center , Alliance, Ohio
- NSA Number:
- NSA-15-000563
- OSTI ID:
- 4131228
- Report Number(s):
- M-6911
- Country of Publication:
- United States
- Language:
- English
Similar Records
REPORT OF PRELIMINARY STRESS-CORROSION CRACKING TESTS OF TYPE-347 STAINLESS STEEL CAPSULES CONTAINING SODIUM HYDROXIDE
RESULTS OF STRESS CORROSION TESTS OF TYPE 347 STAINLESS STEEL IN 500 F pH 10-11 LITHIUM HYDROXIDE
STRESS CORROSION CRACKING OF AUSTENITIC STAINLESS STEEL IN URANYL SULFATE SOLUTIONS
Technical Report
·
Thu Jun 18 00:00:00 EDT 1959
·
OSTI ID:4231848
RESULTS OF STRESS CORROSION TESTS OF TYPE 347 STAINLESS STEEL IN 500 F pH 10-11 LITHIUM HYDROXIDE
Technical Report
·
Thu May 01 00:00:00 EDT 1958
·
OSTI ID:4335013
STRESS CORROSION CRACKING OF AUSTENITIC STAINLESS STEEL IN URANYL SULFATE SOLUTIONS
Journal Article
·
Tue Mar 31 23:00:00 EST 1964
· Corrosion
·
OSTI ID:4010216