PERFORMANCE--TWO-PHASE PRESSURE DROP, BURNOUT, AND HYDRAULIC OSCILLATION OF AN INCLINED TEST SECTION WITH NET STEAM GENERATION AT 1000 PSIA
Technical Report
·
OSTI ID:4128779
Burn-out, pressure-drop, and hydraulic-oscillation tests were performed in an annular geometry inclined 45 deg from the vertical. Data are presented for a uniformly heated rod, 0.540 in. in diameter and 9 ft 2 in. long. located within a circular pipe of 0.875-in. ID. All measurements were made with net steam generation at 1000 psia, and the test variables covered ranges previously studied in the vertical direction. The test results reveal that the performance of the inclined section can be readily determined from that of a vertical channel. (auth)
- Research Organization:
- General Electric Co. Atomic Power Equipment Dept., San Jose, Calif.
- NSA Number:
- NSA-14-025612
- OSTI ID:
- 4128779
- Report Number(s):
- GEAP-3228(Rev.1)
- Country of Publication:
- United States
- Language:
- English
Similar Records
ECCENTRIC ROD BURNOUT AT 1000 lbf/in$sup 2$ WITH NET STEAM GENERATION
BURNOUT CONDITIONS FOR NONUNIFORMLY HEATED ROD IN ANNULAR GEOMETRY. WATER AT 1000 PSIA
HYDRAULIC INSTABILITY IN A NATURAL CIRCULATION LOOP WITH NET STEAM GENERATION AT 1000 PSIA
Journal Article
·
Sun Jul 01 00:00:00 EDT 1962
· Intern. J. Heat and Mass Transfer
·
OSTI ID:4769124
BURNOUT CONDITIONS FOR NONUNIFORMLY HEATED ROD IN ANNULAR GEOMETRY. WATER AT 1000 PSIA
Technical Report
·
Sat Jun 01 00:00:00 EDT 1963
·
OSTI ID:4703410
HYDRAULIC INSTABILITY IN A NATURAL CIRCULATION LOOP WITH NET STEAM GENERATION AT 1000 PSIA
Technical Report
·
Wed Jul 15 00:00:00 EDT 1959
·
OSTI ID:4140419