HYDRODYNAMIC STABILITY OF A BOILING CHANNEL. PART 3
Technical Report
·
OSTI ID:4128516
An extension is made of previous analytical work on the problem of predicting the degree of hydrodynamic stability of a single heated channel across which a constant pressure drop is imposed. The extension concerns the formulation of an explicit model to account for the existence of subcooled boiling, which was essentially ignored in the previous analysis. A computer program (STABLE-4) for the revised analysis is described, and preliminary results are discussed. (auth)
- Research Organization:
- Knolls Atomic Power Lab., Schenectady, N.Y.
- DOE Contract Number:
- W-31-109-ENG-52
- NSA Number:
- NSA-18-003954
- OSTI ID:
- 4128516
- Report Number(s):
- KAPL-2290
- Country of Publication:
- United States
- Language:
- English