skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Design considerations and data for gas-insulated high voltage structures

Conference ·
OSTI ID:4126968

This paper is intended to benefit the person faced with the occasional task of designing gas insulated high-voltage structures or spark gaps and who must decide upon the proper geometry, spacings, gas type, and pressure for reliable voltage-holding. An approach is presented along with a summary of how various factors affect voltage breakdown. The design procedures described apply to situations where the influence of nearby insulators is negligible. The accuracy of the data is estimated to be within 10 to 15 percent, a value usually attained in practice only when one follows the cautionary advice discussed in the paragraphs on materials preparation, gas properties, and conditioning. (auth)

Research Organization:
California Univ., Berkeley (USA). Lawrence Berkeley Lab.
Sponsoring Organization:
USDOE
DOE Contract Number:
W-7405-ENG-48
NSA Number:
NSA-33-011718
OSTI ID:
4126968
Report Number(s):
LBL-4431; CONF-751125-83
Resource Relation:
Conference: IEEE 6. symposium on engineering problems of fusion research, San Diego, California, USA, 17 Nov 1975; Other Information: Orig. Receipt Date: 30-JUN-76
Country of Publication:
United States
Language:
English