A PRELIMINARY REPORT ON MEASUREMENTS OF DIFFUSION PARAMETERS IN WATER BY THE PULSED-NEUTRON METHOD

Technical Report ·
OSTI ID:4122795
The substance of this paper was given in a talk at the American Nuclear Society Meeting in Chicago, June 15, A 25-Mev electron linac, capable of producing 2 x 10/sup 10/ n/pulse by the ( gamma ,n) process in water-cooled lead or tungsten-alloy targets, was used to study neutron diffusion parameters in water. The detector used in the measurements was a small fission counter 0.25 in. in diameter and 0.5 in. long with a 1 mg/cm/sup 2/ coating of U/sup 235/ on the outer electrode. Perturbation effect was determined by comparing the measured decay with the detector in the center to that measured with the detector on the surface. (W.D.M.)
Research Organization:
General Atomic Div., General Dynamics Corp., San Diego, Calif.
DOE Contract Number:
AT(04-3)-167
NSA Number:
NSA-15-000827
OSTI ID:
4122795
Report Number(s):
GA-1584
Country of Publication:
United States
Language:
English

Similar Records

A DYNAMIC DIGITAL DELAY GENERATOR FOR USE IN NEUTRON CHOPPER EXPERIMENTS
Technical Report · Thu Sep 15 00:00:00 EDT 1960 · OSTI ID:4124578

Preliminary analyses of SWINPC beryllium neutron multiplication integral experiments
Journal Article · Wed May 01 00:00:00 EDT 1991 · Fusion Technology; (United States) · OSTI ID:5932089

COMPARATIVE THERMAL FLUX DISTRIBUTIONS, Mn VS. U$sup 235$ DETECTORS