Modeling of the Edwards pipe experiment
The Edwards pipe experiment is used as one of the basic benchmarks for the two-phase flow codes due to its simple geometry and the wide range of phenomena that it covers. Edwards and O`Brien filled 4-m-long pipe with liquid water at 7 MPa and 502 K and ruptured one end of the tube. They measured pressure and void fraction during the blowdown. Important phenomena observed were pressure rarefaction wave, flashing onset, critical two-phase flow, and void fraction wave. Experimental data were used to analyze the capabilities of the RELAP5/MOD3.1 six-equation two-phase flow model and to examine two different numerical schemes: one from the RELAP5/MOD3.1 code and one from our own code, which was based on characteristic upwind discretization.
- OSTI ID:
- 411827
- Report Number(s):
- CONF-951006-; ISSN 0003-018X; TRN: 97:001072
- Journal Information:
- Transactions of the American Nuclear Society, Vol. 73; Conference: Winter meeting of the American Nuclear Society (ANS), San Francisco, CA (United States), 29 Oct - 1 Nov 1995; Other Information: PBD: 1995
- Country of Publication:
- United States
- Language:
- English