NaK PUMP EVALUATION

Technical Report ·
OSTI ID:4116470

Four types of electromagnetic pumps were considered, from an efficiency and weight standpoint, for the task of pumping 11 gpm of 78%K NaK having a temperature of 1000 gas-cooled F with a pressure rise across the pump of 4 psi. The d-c conduction electromagnetic pump appeared to be the most suitable. Characteristics of all four types are listed. (W.D.M.)

Research Organization:
Atomics International. Div. of North American Aviation, Inc., Canoga Park, Calif.
NSA Number:
NSA-15-004084
OSTI ID:
4116470
Report Number(s):
NAA-SR-Memo-5004
Country of Publication:
United States
Language:
English