Title: Rheology and retained gas measurements in Hanford tank 101-SY

Journal Article · · Transactions of the American Nuclear Society
OSTI ID:411590
; ;  [1]
  1. Battelle-Pacific Northwest Labs., Richland, WA (United States)

Several high-level radioactive waste tanks at the Hanford site are known to produce flammable gases. The best known of these tanks is tank 241-SY-101, and to mitigate the safety concerns associated with flammable gas release from this tank, a mixer pump was installed in mid-1993 to mix the waste contents and thereby eliminate or reduce the capability of the waste to retain gas. The mixer pump has proven very effective and only needs to be operated for 30 min about every other day. Large periodic gas release events no longer occur in this tank. However, specific information about the Theological character of the mixed waste and the amount of retained gas has been lacking. In order to determine the amount of gas still retained in the waste and the rheology of the mixed fluid, which is important in establishing the capability of the waste for retaining gas, two instruments were developed to probe the waste in situ. These instruments were the ball rheometer and the void fraction instrument (VFI).

OSTI ID:
411590
Report Number(s):
CONF-951006-; ISSN 0003-018X; TRN: 97:000841
Journal Information:
Transactions of the American Nuclear Society, Vol. 73; Conference: Winter meeting of the American Nuclear Society (ANS), San Francisco, CA (United States), 29 Oct - 1 Nov 1995; Other Information: PBD: 1995
Country of Publication:
United States
Language:
English