Improving the energy efficiency of refrigerators in India
Conference
·
OSTI ID:40784
- Oak Ridge National Lab., TN (United States)
- Consulting Engineer, Cedar Rapids, IA (United States)
Five state-of-the-art, production refrigerators from different manufacturers in India were subjected to a variety of appliance rating and performance evaluation test procedures in an engineering laboratory. Cabinet heat loss, compressor calorimeter, high-ambient pull-down, and closed-door energy consumption tests were performed on each unit to assess the current status of commercially available Indian refrigerators and refrigerator component efficiencies. Daily energy consumption tests were performed at nominal line voltages and at 85% and 115% of nominal voltage to assess the effect of grid voltage variations. These test results were also used to indicate opportunities for effective improvements in energy efficiency. A widely distributed ``generic`` computer model capable of simulating single-door refrigerators with a small interior freezer section was used to estimate cabinet heat loss rates and closed door energy consumption values from basic cabinet and refrigeration circuit inputs. This work helped verify the model`s accuracy and potential value as a tool for evaluating the energy impact of proposed design options. Significant differences ranging from 30 to 90% were seen in the measured performance criterion for these ``comparable`` refrigerators suggesting opportunities for improvements in individual product designs. Modeled cabinet heat loadings differed from experimentally extrapolated values in a range from 2--29%, and daily energy consumption values estimated by the model differed from laboratory data by as little as 3% or as much as 25%, which indicates that refinement of the model may be needed for this single-door refrigerator type. Additional comparisons of experimentally measured performance criteria such as % compressor run times and compressor cycling rates to modeled results are given. The computer model is used to evaluate the energy saving impact of several modest changes to the basic Indian refrigerator design.
- Research Organization:
- Oak Ridge National Lab., TN (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States); Assisting Deployment of Energy Practices and Technologies (ADEPT) Program
- DOE Contract Number:
- AC05-84OR21400
- OSTI ID:
- 40784
- Report Number(s):
- CONF-950624--1; ON: DE95009127
- Country of Publication:
- United States
- Language:
- English
Similar Records
Energy efficiency improvements for refrigerator/freezers using prototype doors containing gas-filled panel insulating systems
Experimental and cost analyses of a one kilowatt-hour/day domestic refrigerator-freezer
Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer
Conference
·
Sat Dec 31 23:00:00 EST 1994
·
OSTI ID:106454
Experimental and cost analyses of a one kilowatt-hour/day domestic refrigerator-freezer
Conference
·
Thu May 01 00:00:00 EDT 1997
·
OSTI ID:474892
Evaluation of design options for improving the energy efficiency of an environmentally safe domestic refrigerator-freezer
Conference
·
Tue Feb 28 23:00:00 EST 1995
·
OSTI ID:10122602