FLECHT low flooding rate cosine test series data report

Technical Report ·
OSTI ID:4077867

The FLECHT Low Flooding Rate Tests were conducted in an improved original FLECHT Test Facility to provide heat transfer coefficient and entrainment data at forced flooding rates of 1 in./sec and below. In addition these tests were performed to supplement parametric effects studied in the original FLECHT program, provide data for reflood model development, repeat original FLECHT tests with new instrumentation and data processing techniques, and to provide data to establish test repeatability. These tests examined the effects of low initial clad temperature, variable stepped and continuously variable flooding rates, housing heat release, run peak power, constant low flooding rates, coolant subcooling, hot and cold channel entrainment, and bundle stored and generated power. Data obtained in sixty four runs which met the test specifications are reported, and include rod clad temperatures, turn around and quench times, heat transfer coefficients, inlet flooding rates, overall mass balances, differential pressures and calculated void fractions in the test section, thimble wall and steam temperatures, exhaust steam and liquid carryover rates, and housing total and rate of heat release. (auth)