LARGE RECORDING POTENTIOMETER ERROSRS CAUSED BY FURNACE LEAKAGE CURRENTS
Large errors in the readings of recording and rec controlling potentiometers used with furnace thermic have been noted to be affected from plus or minus 600/sup o/C upward. An investigation showed that the lO% errors at 1000/sup o/C result of electrical conduction through the ceramic walls and the fused quartz thermocouple sheath. The temperature dependence of the effect corresponded to the tempperature dependence of the electrical resistivity of silica. It is evident that ceramics, as customarily employed, are not adequate for insulating thermocouples from furnace windings at high temperatures. Alternative solutions adequate to the present applications are (1) to suspend the thermocouple out of contact with the furnace walls which are at high temperatures, and (2) to provide a grounded metallic sheath between the furnace wall and the ceramic thermocouple sheath. (B.O.G.)
- Research Organization:
- Argonne National Lab., Ill.
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-15-006185
- OSTI ID:
- 4076717
- Journal Information:
- Rev. Sci. Instr., Journal Name: Rev. Sci. Instr. Vol. Vol: 31
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
A VERSATILE RECORDING POTENTIOMETER
An investigation of temperature measurement methods in nuclear power plant reactor pressure vessel annealing
Thermocouple shield
Technical Report
·
Sun Jan 31 23:00:00 EST 1960
·
OSTI ID:4166328
An investigation of temperature measurement methods in nuclear power plant reactor pressure vessel annealing
Technical Report
·
Wed May 01 00:00:00 EDT 1996
·
OSTI ID:274130
Thermocouple shield
Patent
·
Mon Nov 23 23:00:00 EST 2009
·
OSTI ID:1003017