SNAP III--THERMOELECTRIC GENERATOR ENVIRONMENTAL TEST. VOLUME II

Technical Report ·
DOI:https://doi.org/10.2172/4056524· OSTI ID:4056524
The thermoelectric generator operated for about 250 hr during the entire test program. The efficiency varied approximately 5% of the total performance during the vibration cycle, and remained relatively stable during the acceleration and shock tests. Recovery was complete in all cases. Oscillatory d-c superimposed on the d-c output of the generator was observed durlng the shock and vibratlon tests, and dlsappeared when the environmental forces were discontinued. The maximum d-c ripple was 7.4 mlllivolts rms in the y-Plane durlng the shock and vibratlon cycles. It was concluded that SNAP III thermoelectric generator No. 1G5 is reliable in environments simulating the WS- 117 L Vehicle. (auth)
Research Organization:
Martin Co. Nuclear Div., Baltimore
Sponsoring Organization:
USDOE
NSA Number:
NSA-15-014829
OSTI ID:
4056524
Report Number(s):
MND-P-2101-II
Country of Publication:
Country unknown/Code not available
Language:
English

Similar Records

SNAP-III--THERMOELECTRIC GENERATOR ENVIRONMENTAL TEST. VOLUME III
Technical Report · Thu Dec 31 23:00:00 EST 1959 · OSTI ID:4174183

SNAP-III--THERMOELECTRIC GENERATOR ENVIRONMENTAL TEST
Technical Report · Sat Aug 01 00:00:00 EDT 1959 · OSTI ID:4211603

PERFORMANCE DATA AND ENVIRONMENTAL TEST RESULTS OF SNAP III
Journal Article · Sat Dec 31 23:00:00 EST 1960 · Planetary Space Sci. · OSTI ID:4018565