MEASUREMENT OF THE DOPPLER BROADENING OF GAMMA-RAY ENERGY WITH Ge(Li) DETECTOR.
Journal Article
·
· J. Nucl. Sci. Technol. 8: 48-50(Jan 1971).
- Research Organization:
- Japan Atomic Energy Research Inst., Tokai
- Sponsoring Organization:
- USDOE
- NSA Number:
- NSA-25-031208
- OSTI ID:
- 4054104
- Journal Information:
- J. Nucl. Sci. Technol. 8: 48-50(Jan 1971)., Journal Name: J. Nucl. Sci. Technol. 8: 48-50(Jan 1971).
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
MEASUREMENT OF HIGH-ENERGY $gamma$-RAYS WITH Ge(Li) DETECTORS
STUDY OF DOPPLER-BROADENED ANNIHILATION RADIATION IN METALS WITH A Ge(Li) DETECTOR.
Natural $gamma$-ray background measured with Ge(Li) detector
Journal Article
·
Fri Dec 31 23:00:00 EST 1965
· Nuclear Instruments and Methods (Netherlands) Formerly Nucl. Instrum. Changed to Nucl. Instrum. Methods Phys. Res.
·
OSTI ID:4563620
STUDY OF DOPPLER-BROADENED ANNIHILATION RADIATION IN METALS WITH A Ge(Li) DETECTOR.
Journal Article
·
Fri Dec 31 23:00:00 EST 1971
· Nuovo Cim. 10B: No. 1, 334-8(11 Jul 1972).
·
OSTI ID:4668708
Natural $gamma$-ray background measured with Ge(Li) detector
Journal Article
·
Mon Oct 01 00:00:00 EDT 1973
· Sov. At. Energy (Engl. Transl.), v. 35, no. 4, pp. 941-942
·
OSTI ID:4259472
Related Subjects
CARBON 12
CARBON ISOTOPES C-12/energy-level transition in
Doppler broadening of 4.43-MeV
(E)
DOPPLER EFFECT
ENERGY LEVELS
GAMMA RADIATION
GAMMA RADIATION/Doppler broadening of
measurement using lithium- drifted germanium detectors
LITHIUM 7
LITHIUM ISOTOPES Li-7/energy-level transition in
Doppler broadening of 0.477-MeV
(E)
N26120 --Instrumentation--Radiation Detection Instruments--Nuclear Spectroscopic Instrumentation
N36330* --Physics (Nuclear)--Nuclear Properties & Reactions
6 <= A <= 19--Energy Levels & Transitions
RADIATION DETECTORS
RADIATION DETECTORS
SEMICONDUCTOR (GERMANIUM)/ performance of lithium-drifted
for measurement of Doppler broadening of $gamma$- rays
SEMICONDUCTORS
TRANSIENTS
CARBON ISOTOPES C-12/energy-level transition in
Doppler broadening of 4.43-MeV
(E)
DOPPLER EFFECT
ENERGY LEVELS
GAMMA RADIATION
GAMMA RADIATION/Doppler broadening of
measurement using lithium- drifted germanium detectors
LITHIUM 7
LITHIUM ISOTOPES Li-7/energy-level transition in
Doppler broadening of 0.477-MeV
(E)
N26120 --Instrumentation--Radiation Detection Instruments--Nuclear Spectroscopic Instrumentation
N36330* --Physics (Nuclear)--Nuclear Properties & Reactions
6 <= A <= 19--Energy Levels & Transitions
RADIATION DETECTORS
RADIATION DETECTORS
SEMICONDUCTOR (GERMANIUM)/ performance of lithium-drifted
for measurement of Doppler broadening of $gamma$- rays
SEMICONDUCTORS
TRANSIENTS