Junction-FET dosimeter

Journal Article · · J. Appl. Phys., v. 47, no. 4, pp. 1732-1734
DOI:https://doi.org/10.1063/1.322763· OSTI ID:4048730
The performance of a new junction-FET dosimeter and its application to the beam profile measurement are presented. One of the two junction FET's making up an astable multivibrator is used as a small-size (approx.0.4x0.4 mm) high- level dose detector. The irradiated dose can be estimated by the amount of the decrease of the oscillator period of the multivibrator. The distinct advantages in its small size and superior resistive property to radiation effect enable us to measure the cross-sectional profile of the electron beam from a linac with high spatial resolution of about 0.4 mm.
Research Organization:
Electrotechnical Laboratory, Tanashi, Tokyo, Japan
Sponsoring Organization:
USDOE
NSA Number:
NSA-33-029236
OSTI ID:
4048730
Journal Information:
J. Appl. Phys., v. 47, no. 4, pp. 1732-1734, Journal Name: J. Appl. Phys., v. 47, no. 4, pp. 1732-1734; ISSN JAPIA
Country of Publication:
United States
Language:
English