Application of EPRI risk-based inservice inspection procedure to combustion engineering design of nuclear power plant
Conference
·
OSTI ID:404248
- ABB Combustion Engineering, Windsor, CT (United States). Nuclear Operations
- Entergy Operations-ANO2, Russellville, AR (United States)
The EPRI developed risk-based inservice inspection procedure is used to select the elements for inservice inspection on a section of the high pressure safety injection system of the Entergy Operations ANO2 nuclear plant. This plant is the pilot plant in a six utility-eleven plant EPRI tailored collaboration program to apply the general EPRI procedures to Combustion Engineering NSSS designs. The procedure results in a reduction of candidate inspection locations from 14, based on current ASME Section XI rules for B-J welds to 3, based on the risk-based selection criteria.
- OSTI ID:
- 404248
- Report Number(s):
- CONF-960706--; ISBN 0-7918-1786-5
- Country of Publication:
- United States
- Language:
- English
Similar Records
A practical implementation procedure for risk-based inservice inspection
Update on the EPRI power generation risk-based inservice inspection pilot plant studies
A practical approach to risk-based inservice inspection in U.S. nuclear power plants
Conference
·
Mon Jul 01 00:00:00 EDT 1996
·
OSTI ID:251005
Update on the EPRI power generation risk-based inservice inspection pilot plant studies
Conference
·
Tue Jul 01 00:00:00 EDT 1997
·
OSTI ID:489072
A practical approach to risk-based inservice inspection in U.S. nuclear power plants
Conference
·
Sat Nov 30 23:00:00 EST 1996
·
OSTI ID:404243