HNPF SODIUM SYSTEM IHX FREQUENCY RESPONSE
Technical Report
·
OSTI ID:4036200
BS>Frequency response characteristics of an analog model of the Hallam Nuclear Power Facility scdium system are presented. The system consists of the IHX, primary and secondary scdium hydraulics plus asscciated flow and temperature control subsystems. Correlations of the IHK heat parameter system frequency response is reasonable at low frequencies, but differs markedly in the high frequency spectrum. The responses of secondary outlet temperatures to output signals at maximum and minimum power levels are also included. (J.R.D.)