Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

SPECTROPHOTOMETRIC DETERMINATION OF RHENIUM WITH 4-METHYLNIOXIME

Journal Article · · Talanta (England)
A simple method applicable to the spectrophotometric determination of less than 0.001% to more than 1.0% of rhenium in molybdenite concentration and ln "molybdenite roaster flue dust" has been developed. Interfering elements commonly found in these materials are removed in three operations: evaporation with hydrochloric acid, precipitation of hydrous oxides with ammonia, and formation of organometallic compounds with ethyl xanthate and chloroform extraction. The method is based on the formation of a soluble, stable, yellow- green rhenium-4-methylnioxime chelate where rhenium/sup VII/ is reduced by tin/ sup II/ chloride in a dilute hydrochloric acid solution in the presence of 4methylnioxime (4-methyl-1: 2-cyclohexanedionedioxime). The color develops in less than 5 min and the chloroform extract shows a maximum absorption at 436 m mu . The calibration curve corforms to Beer's law. The molar extinction coefficient for rhenium-4-methylnioxime is abcut 6.89 x 104 as compared to less than 4.5 x l0/sup 4/ reported for other methods for rhenium. (auth)
Research Organization:
Univ. of Alabama, University
NSA Number:
NSA-15-023473
OSTI ID:
4034264
Journal Information:
Talanta (England), Journal Name: Talanta (England) Vol. Vol: 7; ISSN TLNTA
Country of Publication:
Country unknown/Code not available
Language:
English