Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

Effect of temperature on steam generator fretting-wear

Book ·
OSTI ID:403396
; ; ;  [1]
  1. Atomic Energy of Canada Limited, Chalk River, Ontario (Canada). Chalk River Labs.
Flow-induced vibration of steam generator tubes results in fretting-wear damage at the tube-to-support locations. A test program was conducted to assess the effect of temperature on steam generator tube fretting-wear. Tests were performed using lattice bar supports, at temperatures ranging from 25 to 315 C. A parameter called work-rate was used to normalize the wear rates and interpret the results in terms of wear coefficients. The role of corrosion was investigated and Scanning Electron Microscope examinations of fretted samples were performed to provide complementary information and identify pre-eminent fretting-wear mechanisms. The results revealed a significant effect of temperature on steam generator tube fretting-wear. Wear rates measured at elevated temperature are greater than those measured at room temperature. A peak in damage rate is observed at approximately 200 C, beyond which wear decreases with temperature.
OSTI ID:
403396
Report Number(s):
CONF-960706--; ISBN 0-7918-1775-X
Country of Publication:
United States
Language:
English

Similar Records

Steam generator fretting-wear damage: A summary of recent findings
Journal Article · Sun Aug 01 00:00:00 EDT 1999 · Journal of Pressure Vessel Technology · OSTI ID:687524

Experimental fretting-wear studies of steam generator materials
Journal Article · Tue Oct 31 23:00:00 EST 1995 · Journal of Pressure Vessel Technology · OSTI ID:131621

PWR steam generator tube fretting and fatigue wear: Final report