J{sub IC} evaluation of the smooth and the side-grooved CT specimen in the reactor pressure vessel steel (SA508-3)
Conference
·
OSTI ID:402993
- Dong-A Univ., Pusan (Korea, Republic of). Dept. of Mechanical Engineering
The elastic-plastic fracture toughness J{sub IC} of SA508-3 forging steel was investigated by using CT-type specimens. The thickness of the smooth specimen is B{sub 0} = 25.4 mm and the side groove specimen is B{sub N} = 20.4 mm and the side groove deep is S{center_dot}G = [(B{sub 0} {minus} B{sub N})/B{sub 0}] {times} 100 = 19.7% and the groove angle is 90{degree}. The J{sub IC} tests estimated according to the method proposed in the ASTM E813-81 and JSME S001-81. The side-grooved specimen have the advantage of J{sub IC} estimation, it is much easier to determine the onset of ductile tearing by the R-curve method and it improved accuracy and scatter of the toughness values thus determined, provided all the size-requirements for the specimen prescribed in the JSME method were satisfied. But it is difficult to find by the ASTM method. The critical stretched zone width (SZW{sub C}) of the side-grooved specimens found to be smaller than that previously determined for the standard CT specimens without side-grooves. This was attributed to higher triaxiality produced by the side-grooves. The stretched zone width method gave slightly larger J{sub IC} values than those by the R-curve method for SA508-3, as has been observed for the standard specimen without side-groove.
- OSTI ID:
- 402993
- Report Number(s):
- CONF-940473--; ISBN 1-880653-15-X
- Country of Publication:
- United States
- Language:
- English
Similar Records
Effect of temperature on the fracture toughness in the nuclear reactor pressure vessel steel (SA508-3)
Effects of specimen thickness and side-groove on fracture toughness of JN1 austenitic stainless steel rolled plate at liquid helium temperature
Effect of crack length and side grooves on the ductile fracture toughness properties of ASTM A533 steel
Conference
·
Fri Dec 30 23:00:00 EST 1994
·
OSTI ID:433626
Effects of specimen thickness and side-groove on fracture toughness of JN1 austenitic stainless steel rolled plate at liquid helium temperature
Journal Article
·
Sun Jun 01 00:00:00 EDT 1997
· Advances in Cryogenic Engineering
·
OSTI ID:476722
Effect of crack length and side grooves on the ductile fracture toughness properties of ASTM A533 steel
Technical Report
·
Mon Dec 31 23:00:00 EST 1979
·
OSTI ID:5492077