Skip to main content
U.S. Department of Energy
Office of Scientific and Technical Information

MEASUREMENT OF ABSORPTION OF VITAMIN B$sub 12$ BY WHOLE-BODY GAMMA SPECTROMETRY

Journal Article · · Blood (U.S.)
OSTI ID:4024564
A technic is described to measure directly the intestinal absorption of radiovitamin B/sub 12/ by using a whole-body gamma spectrometer. A double tracer technic is used, and the amounts of free and intrinsic factor bound vitamin B/sub 12/, respectively, retained in the body after final excretion of unabsorbed radioactivity, are measured. The present method is simple and quantitative. The primary advantage of the whole-body counter for measuring absorption of Cobalt- labeled B/sub 12/ is that is can measure less than 0.1 mu c with a high degree of accuracy. Whole-body counting substitutes a rapid and simple measurement for the difficult and tedious collection and radiochemical analysis of excreta. (auth)
Research Organization:
Brookhaven National Lab., Upton, N.Y.
NSA Number:
NSA-15-024660
OSTI ID:
4024564
Report Number(s):
BNL-5274; 0006-4971
Journal Information:
Blood (U.S.), Journal Name: Blood (U.S.) Vol. Vol: 18; ISSN BLOOA
Country of Publication:
United States
Language:
English