WELDING OF BORON STAINLESS STEEL CONTROL RODS. Pathfinder Atomic Power Plant
Technical Report
·
OSTI ID:4020767
The results of welding fabrication studies led to the selection of control rods fabricated of 1/4-in. flat plates and manually welded with type E308- 16 coated stainless steel electrodes. The technique developed is used for fabricating control rods for the Allis-Chalmers Critical Test Facility and the Pathfinder reactor. (B.O.G.)
- Research Organization:
- Allis-Chalmers Mfg. Co. Atomic Energy Div., Milwaukee
- NSA Number:
- NSA-15-025165
- OSTI ID:
- 4020767
- Report Number(s):
- ACNP-6106
- Country of Publication:
- United States
- Language:
- English