skip to main content
OSTI.GOV title logo U.S. Department of Energy
Office of Scientific and Technical Information

Title: Real-time measurement of toroidal rotation (abstract)

Journal Article · · Review of Scientific Instruments
DOI:https://doi.org/10.1063/1.1323495· OSTI ID:40204875

One of the important goals in Columbia's HBT-EP tokamak program is the improvement in the stability of tokamak plasmas by controlling the bulk plasma flow relative to the conducting wall. The method for active plasma flow control in HBT-EP is the application of oscillating resonant magnetic perturbations to oppose the velocity of magnetic islands at the q=2 surface. Real time (10 kHz) feedback control without inserting a material probe necessitates the use of an optical toroidal rotation measurement whose data is available during the shot. This is being accomplished in a novel way by seeding the deuterium plasma with 5%--10% helium and measuring the Doppler shift of the chord-integrated emission of the HeII (n=4{yields}3) line at 4686 Aa. Since the electron temperature is expected to be about 30 eV at the q=2 surface, helium is not fully stripped. The shift in wavelength is calculated by measuring the change in intensity as the line moves across the passband of an interference filter that varies linearly. Filters with less than 0.2% variation from a perfectly linear slope have been obtained. Fluctuations in the plasma emission are removed by having two detectors observe the same volume of plasma. This is achieved by splitting the optical view with a 'Y' composed of randomized optical fibers. One detector views the plasma through a filter whose passband has a negative slope and the other channel views it through a positive-slope filter. Systematic differences such as detector sensitivity, amplifier gain, fiber losses, etc. are compensated by normalizing each signal to the signal at a particular reference time. The ratio of signals at two different times does not depend on any detector or circuit characteristic that remains constant. The Doppler shift, relative to the reference time, is a function only of the slope of the filter's transmission. The Doppler shift at the HeII impurity emisson line is 0.25 Aa for a toroidal rotation of 3 km/s, and the slope of the filter passband is 8%--10% per Aa, resulting in a 4% variation in signal level relative to the other channel.

Sponsoring Organization:
(US)
OSTI ID:
40204875
Journal Information:
Review of Scientific Instruments, Vol. 72, Issue 1; Other Information: Othernumber: RSINAK000072000001000966000001; 714101CON; PBD: Jan 2001; ISSN 0034-6748
Publisher:
The American Physical Society
Country of Publication:
United States
Language:
English