ANALOG SYSTEMS FOR THE T7 FLUX TRAP CORE
Technical Report
·
OSTI ID:4014387
Analog computer studies were conducted using three different models of the T7 flux trap core subjected to a variable acceleration representing the effect of ship's motion. One model was the batch model developed previously. The other two were flow models having equations of like form but using a different method of combining the heated twophase length and the riser length. The original model combines the two sections on the basis of length. The modified floww model combines the two sections on the basis of the driving head developed across each. The three models were compared in the steady state with an apparent step change in acceleration te 1.5g. The results were in close agreement, the batch model showing a velocity variation of 20% compared to 17% for the modified-flow model and the variations in void fraction of 24 and 30%, respectively. The differences are attributed to the basic differences in the models. The steady-state model and modified core model were compared with a harmonic excitation of plus or minus 0.55 g. At the expected operating frequency of 0.16 cps, the transient nature of the modified flow model gives a maximum neutron flux of 158% compared to 178% for the batch model. The peaks are lower for the flow model than for the batch model at frequencies above 0.1 cps, but slightly higher below 0.1 cps. The Dome and Downcomer models were studied, though not as extensively as the core model. The Dome model was improved over that which was previously used by incorporating energy terms which were neglected. It was determined that the Downcomer model can be improved by incorporating in it a variable time delay, which will reduce the peak in neutron flux which occurs at 0.04 cps. (auth)
- Research Organization:
- General Electric Co. Flight Propulsion Lab., Dept., San Ramon, Calif.
- NSA Number:
- NSA-15-025636
- OSTI ID:
- 4014387
- Report Number(s):
- GEAP-3575
- Country of Publication:
- United States
- Language:
- English
Similar Records
IMPROVED CHIMNEY FOR BOILING WATER REACTOR
SUMMARY PHYSICS REPORT OF T7 TANKER REACTOR CONTROL SYSTEM
Experiment DTA report for semiscale transparent vessel countercurrent flow tests
Patent
·
Wed Aug 01 00:00:00 EDT 1962
·
OSTI ID:4797420
SUMMARY PHYSICS REPORT OF T7 TANKER REACTOR CONTROL SYSTEM
Technical Report
·
Tue Jan 17 23:00:00 EST 1961
·
OSTI ID:4026858
Experiment DTA report for semiscale transparent vessel countercurrent flow tests
Technical Report
·
Wed Oct 01 00:00:00 EDT 1975
·
OSTI ID:4141453