VACUUM SYSTEM FOR A 1000-Bev ACCELERATOR

Technical Report ·
OSTI ID:4009450
Parameters of outgassing and vacuum maintenance are analyzed. It was thought that cryogenic pumping and getter-ion pumping would be necessary to achieve desired pressures in the accelerating tube. Use of a manifold to eliminate poor vacuum chamber conductance is also recommended for consideration. (J.R.D.)