Delayed-neutron systems for failed fuel location in CANDU reactors
Conference
·
· IEEE Trans. Nucl. Sci., v. NS-23, no. 1, pp. 325-330
OSTI ID:4004818
The engineering and operational requirements for failed-fuel location systems in CANDU reactors are constantly evolving and the effects of these changes on system design are discussed, with particular reference to the location system for the Bruce G.S. An experimental program to optimize the counting arrangement for the Bruce failed-fuel location system is described in detail.
- Research Organization:
- Atomic Energy of Canada, Ltd., Chalk River, Ont.
- NSA Number:
- NSA-33-032271
- OSTI ID:
- 4004818
- Journal Information:
- IEEE Trans. Nucl. Sci., v. NS-23, no. 1, pp. 325-330, Journal Name: IEEE Trans. Nucl. Sci., v. NS-23, no. 1, pp. 325-330; ISSN IETNA
- Country of Publication:
- United States
- Language:
- English
Similar Records
Failed fuel location in CANDU-PHW reactors using a feeder scanning technique
LOCATING FAILED FUEL IN WATER REACTORS
Plutonium Consumption Program, CANDU Reactor Project: Feasibility of BNFP Site as MOX Fuel Supply Facility. Final report
Conference
·
Sat Jan 31 23:00:00 EST 1976
· IEEE Trans. Nucl. Sci., v. NS-23, no. 1, pp. 321-324
·
OSTI ID:4004795
LOCATING FAILED FUEL IN WATER REACTORS
Journal Article
·
Sat Jul 01 00:00:00 EDT 1961
· Nucleonics (U.S.) Ceased publication
·
OSTI ID:4038421
Plutonium Consumption Program, CANDU Reactor Project: Feasibility of BNFP Site as MOX Fuel Supply Facility. Final report
Technical Report
·
Fri Jun 30 00:00:00 EDT 1995
·
OSTI ID:82369
Related Subjects
*BRUCE-1 REACTOR-- FAILED ELEMENT DETECTION
*BRUCE-2 REACTOR-- FAILED ELEMENT DETECTION
*BRUCE-3 REACTOR-- FAILED ELEMENT DETECTION
*BRUCE-4 REACTOR-- FAILED ELEMENT DETECTION
*CANDU TYPE REACTORS-- FAILED ELEMENT DETECTION
*FAILED ELEMENT MONITORS
210400* --Nuclear Power Plants--Power Reactors
Non- Breeding
Otherwise Moderated or Unmoderated
BF3 COUNTERS
DELAYED NEUTRONS
N77400* --Reactors--Power Reactors
Non-breeding
Otherwise Moderated or Unmoderated
*BRUCE-2 REACTOR-- FAILED ELEMENT DETECTION
*BRUCE-3 REACTOR-- FAILED ELEMENT DETECTION
*BRUCE-4 REACTOR-- FAILED ELEMENT DETECTION
*CANDU TYPE REACTORS-- FAILED ELEMENT DETECTION
*FAILED ELEMENT MONITORS
210400* --Nuclear Power Plants--Power Reactors
Non- Breeding
Otherwise Moderated or Unmoderated
BF3 COUNTERS
DELAYED NEUTRONS
N77400* --Reactors--Power Reactors
Non-breeding
Otherwise Moderated or Unmoderated