FERROUS AND CERIC SULPHATE DOSIMETERS: INTERPRETATION OF THE EFFECT OF RADIATION QUALITY
Technical Report
·
OSTI ID:4002326
The number of ferric and cerous ions produced in ferrous and ceric sulfate dosimeters, per 100 ev of absorbed energy, depends on the quality of radiation used. In a detailed interpretation of this variation of yield with radiation quality, the solution to a diffusion-kinetic equation for a one-radical model was combined with a consideration of the spectrum of local energy dissipation. The mathematical formulation of the one-radical model and the results of calculations for gamma rays, alpha particles, and beta particles are given. The large disagreement with experimental results was considered to be due to the unrealistic model used. (M.C.G.)
- Research Organization:
- Sao Paulo. Brizil. Universidade. Insitiuto de Energia Atomica
- NSA Number:
- NSA-15-019540
- OSTI ID:
- 4002326
- Report Number(s):
- IEA-40
- Country of Publication:
- Country unknown/Code not available
- Language:
- English
Similar Records
A THEORETICAL INTERPRETATION OF THE EFFECT OF RADIATION QUALITY ON YIELD IN THE FERROUS AND CERIC SULFATE DOSIMETERS
LABORATORY MANUAL FOR SOME HIGH-LEVEL CHEMICAL DOSIMETERS: FERROUS SULPHATE, OXALIC ACID, CERIC SULPHATE, POLYVINYLCHLORIDE FOILS
Absorbed gamma and electron radiation dose with the ceric sulfate dosimeter
Journal Article
·
Thu Oct 01 00:00:00 EDT 1959
· Radiation Research
·
OSTI ID:4224739
LABORATORY MANUAL FOR SOME HIGH-LEVEL CHEMICAL DOSIMETERS: FERROUS SULPHATE, OXALIC ACID, CERIC SULPHATE, POLYVINYLCHLORIDE FOILS
Technical Report
·
Sat Jul 01 00:00:00 EDT 1961
·
OSTI ID:4843639
Absorbed gamma and electron radiation dose with the ceric sulfate dosimeter
Journal Article
·
Wed Dec 31 23:00:00 EST 1980
· Annu. Book ASTM Stand.; (United States)
·
OSTI ID:5609765