Cost-effective method to improve cathodic protection systems
Journal Article
·
· Pipe Line and Gas Industry
OSTI ID:39940
- Memphis Light, Gas and Water Div., TN (United States)
By installing a rectifier efficiency filter, annual operating costs can be reduced by generating a more effective cathodic protection system. The cathodic protection analyzer (CPA) has been used to conduct a cathodic protection potential survey for two Memphis Light, Gas and Water Division`s 18-in. transmission lines. The two lines, under impressed current cathodic protection, were installed in 1928 and 1940. Both operate at 260 psig and consist of 5.163 mi of 18-in. diameter coated welded steel.
- OSTI ID:
- 39940
- Journal Information:
- Pipe Line and Gas Industry, Journal Name: Pipe Line and Gas Industry Journal Issue: 3 Vol. 78; ISSN PLGIFV
- Country of Publication:
- United States
- Language:
- English