Experience with small-gap undulators
Conference
·
OSTI ID:394463
Over the past year, we have gained some experience with small-gap undulators through operation of the NSLS Prototype Small-Gap Undulator (PSGU). PSGU is a small R&D insertion device intended for investigation of the fundamental limitations of small-gap devices. At the same time, PSGU aptly demonstrates the enhanced performance offered by such devices, through generation of radiation with a 16 mm period pure-permanent-magnet undulator. In what follows, we present a brief description of PSGU and a summary of operating experience to date. This includes a spectrum of the undulator radiation produced at a 5.6 mm magnet gap, and the appearance of operational limitations, namely lifetime degradation, beam instabilities, and increased bremsstrahlung radiation.
- Research Organization:
- Brookhaven National Lab., Upton, NY (United States)
- Sponsoring Organization:
- USDOE, Washington, DC (United States)
- DOE Contract Number:
- AC02-76CH00016
- OSTI ID:
- 394463
- Report Number(s):
- BNL--63150; CONF-9510119--38; ON: DE97000136
- Country of Publication:
- United States
- Language:
- English
Similar Records
Experience with small-gap undulators
NSLS prototype small-gap undulator (PSGU)
Impedance of a small-gap undulator vacuum chamber
Journal Article
·
Sun Sep 01 00:00:00 EDT 1996
· Review of Scientific Instruments
·
OSTI ID:390544
NSLS prototype small-gap undulator (PSGU)
Conference
·
Mon Dec 31 23:00:00 EST 1990
·
OSTI ID:5473112
Impedance of a small-gap undulator vacuum chamber
Conference
·
Thu Jul 01 00:00:00 EDT 1993
·
OSTI ID:10172068