Experience with small-gap undulators

Conference ·
OSTI ID:394463
Over the past year, we have gained some experience with small-gap undulators through operation of the NSLS Prototype Small-Gap Undulator (PSGU). PSGU is a small R&D insertion device intended for investigation of the fundamental limitations of small-gap devices. At the same time, PSGU aptly demonstrates the enhanced performance offered by such devices, through generation of radiation with a 16 mm period pure-permanent-magnet undulator. In what follows, we present a brief description of PSGU and a summary of operating experience to date. This includes a spectrum of the undulator radiation produced at a 5.6 mm magnet gap, and the appearance of operational limitations, namely lifetime degradation, beam instabilities, and increased bremsstrahlung radiation.
Research Organization:
Brookhaven National Lab., Upton, NY (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH00016
OSTI ID:
394463
Report Number(s):
BNL--63150; CONF-9510119--38; ON: DE97000136
Country of Publication:
United States
Language:
English

Similar Records

Experience with small-gap undulators
Journal Article · Sun Sep 01 00:00:00 EDT 1996 · Review of Scientific Instruments · OSTI ID:390544

NSLS prototype small-gap undulator (PSGU)
Conference · Mon Dec 31 23:00:00 EST 1990 · OSTI ID:5473112

Impedance of a small-gap undulator vacuum chamber
Conference · Thu Jul 01 00:00:00 EDT 1993 · OSTI ID:10172068