Body contour determination and validation for Bremsstrahlung SPECT imaging
Journal Article
·
· Journal of Nuclear Medicine
OSTI ID:394092
- Cooper Hospital/Univ. Medical Center, Camden, NJ (United States)
The purpose of this study was to validate a previously reported body contour measurement using Compton backscatter sources with bremsstrahlung SPECT imaging. Bremsstrahlung SPECT imaging was performed with {sup 32}P using a dual-headed camera system fitted with medium-energy, parallel-hole collimators. Two sources of {sup 99m}Tc were placed directly on each collimator. Energy windows of 100 keV {+-} 25% were used to image the {sup 32f}P and also to record the Compton scatter from the {sup 99m}Tc sources. Eleven patients enrolled in clinical Phase I therapeutic protocols were injected with {sup 32}P-chromic phosphate and SPECT images were acquired and reconstructed in the transaxial plane. The {sup 32}P distribution and the patient body contour were both visualized in these slices. The anteroposterior and lateral patient dimensions were measured by generating count profiles parallel to the anteroposterior and lateral body contour, respectively, at the midline in a transaxial slice. The distance in centimeters between the two centroids of each profile is representative of the anteroposterior and lateral dimensions and was determined for each patient. These anteroposterior and lateral dimensions were compared to the same distance measurements made in these patients by CT in an anatomically comparable transaxial slice. A cylindrical SPECT phantom was also studied to further validate the contour measurements. The mean percent difference in the patient dimension measurements between SPECT and CT was -0.8% with a range of -8.5% to 9.9%. The percent difference between the known and SPECT measured dimensions in the cylindrical phantom was 0.5%. The two external Compton scatter source method is accurate for determining the body contour. 20 refs., 2 figs., 1 tab.
- OSTI ID:
- 394092
- Journal Information:
- Journal of Nuclear Medicine, Journal Name: Journal of Nuclear Medicine Journal Issue: 3 Vol. 37; ISSN JNMEAQ; ISSN 0161-5505
- Country of Publication:
- United States
- Language:
- English
Similar Records
Angled-collimator SPECT (A-SPECT): an improved approach to cranial single photon emission tomography
Segmentation of the body and lungs from Compton scatter and photopeak window data in SPECT: A Monte-Carlo investigation
High spatial resolution technique for SPECT using a fan-beam collimator
Journal Article
·
Sun Jul 01 00:00:00 EDT 1984
· J. Nucl. Med.; (United States)
·
OSTI ID:6982981
Segmentation of the body and lungs from Compton scatter and photopeak window data in SPECT: A Monte-Carlo investigation
Journal Article
·
Wed Jan 31 23:00:00 EST 1996
· IEEE Transactions on Medical Imaging
·
OSTI ID:207907
High spatial resolution technique for SPECT using a fan-beam collimator
Journal Article
·
Sun Aug 01 00:00:00 EDT 1993
· IEEE Transactions on Nuclear Science (Institute of Electrical and Electronics Engineers); (United States)
·
OSTI ID:6062229