Outage dose reduction achievements during shorter refueling outages
- Limerick Generating Station, Sanatoga, PA (United States)
Achievement of dose reduction goals has been demonstrated at the Limerick Generating Station during the past three refueling outages in 1995-96. Shorter refueling outages were accomplished by carefully selecting outage work and thoroughly planning the work. Limerick Unit 1 completed its outage in 35 d; Unit 2 in 23 d in 1995; Unit 1 completed its outage in 24 d in 1996. The four previous outages at Unit I had taken from 100 to 127 days. European plants were visited by plant supervisors to develop improved management approaches to optimizing outage performance from work planning to work implement. Cofrentes in Spain and KKL Leibstadt in Switzerland were visited in 1994 because of their similar design and outage durations consistently below 35 d. This paper describes the radiation protection practices observed at European plants and implemented at Limerick to achieve efficiency of work practices and adequacy of radiological controls. Specific radiation protection initiatives discussed include electronic dosimetry system, break areas, wash sinks, scrub suits, zone mapping and self-monitoring. Outage achievements in 1995 and 1996 has assured Limerick continued BWR industry leadership as the lowest annual person-rem BWRs in the U.S..
- OSTI ID:
- 394081
- Report Number(s):
- CONF-9607135--
- Journal Information:
- Health Physics, Journal Name: Health Physics Journal Issue: Suppl.6 Vol. 70; ISSN HLTPAO; ISSN 0017-9078
- Country of Publication:
- United States
- Language:
- English