LaSalle snubber replacement using E-BAR technology

Conference ·
OSTI ID:389966
; ;  [1]; ;  [2];  [3]
  1. ComEd, Chicago, IL (United States)
  2. Sargent and Lundy, Chicago, IL (United States)
  3. Lisega, Inc., Newport, TN (United States)

Snubbers, whether they are located on safety-related piping of nonsafety-related piping, present a significant challenge to today`s nuclear stations as they look for ways to reduce Operations and Maintenance (O and M) budgets. Nonsafety-related snubbers have recently started to draw more attention as the Nuclear Regulatory Commission considers requirements for the testing of nonsafety-related snubbers. This paper addresses the replacement of nonsafety-related snubbers, utilizing E-BAR technology, on two systems at ComEd`s LaSalle County Nuclear Station.

OSTI ID:
389966
Report Number(s):
CONF-960426--
Country of Publication:
United States
Language:
English

Similar Records

Snubber reduction program at LaSalle County Station, Units 1 and 2
Conference · Wed Dec 31 23:00:00 EST 1986 · Trans. Am. Nucl. Soc.; (United States) · OSTI ID:6866985

Snubber reduction program at the Byron Station, Unit 1
Conference · Wed Dec 31 23:00:00 EST 1986 · Trans. Am. Nucl. Soc.; (United States) · OSTI ID:6942757

Snubber reduction
Conference · Mon Mar 31 23:00:00 EST 1986 · Proc. Am. Power Conf.; (United States) · OSTI ID:6982198