Emittance measurement techniques used in the 1 MeV RFQ for the PET isotope linac at Fermilab

Conference ·
OSTI ID:385475
; ;  [1];  [2]
  1. Fermi National Accelerator Lab., Batavia, IL (United States)
  2. Science Applications International Corp., San Diego, CA (United States)
Beam emittance measurements have been performed on the {sup 3}He{sup +} beam at the PET isotope production accelerator, being commissioned at Fermilab for the Biomedical Research Foundation in Shreveport, Louisiana, USA. Emittances have been measured at injection to and extraction from the first RFQ, at 20 keV and 1 MeV, respectively. A single slit followed by a 48 electrode collector is used in the standard way to measure the divergence of the {sup 3}He{sup +} beam as a function of position. Noise reduction operations have been developed, both in hardware and software. These techniques and the emittance measurement results are presented.
Research Organization:
Fermi National Accelerator Lab., Batavia, IL (United States)
Sponsoring Organization:
USDOE, Washington, DC (United States)
DOE Contract Number:
AC02-76CH03000
OSTI ID:
385475
Report Number(s):
FNAL/C--96/309-E; CONF-9608123--38; ON: DE96050558
Country of Publication:
United States
Language:
English